The Case of the Overeager Pump

THE MYSTERY The freshwater division of a municipal water works complained that one of three pumps at a lift station was running constantly, causing the hydrostatic chamber to drain empty. This, in turn, caused the other pumps to come on, and eventually put so much pressure on the system that the pipes burst. The system was only rated for 93 psi, but with the other pumps running the pressure…

read more

The Case of the Transplanted Oven

THE MYSTERY An aircraft company purchased a large used oven and had it moved to their location. They set up the oven and lit it, but it would not stay lit. The customer removed duct work and replaced the burner, but the oven still refused to stay lit. THE CLUES…

read more

The Case of the Salt Bath Burner Gone Bad

THE MYSTERY A local company had a power failure during the night. They have a large salt bath with two burners. One burner relit automatically but the second would not relight — and upon manual relighting would not stay lit.

read more

The Case of the Stuck Ink Dryer

THE MYSTERY A glass company who screen prints logos on customer glass called ACES because the mechanism that advances the glass through the ink dryer wasn’t working.THE CLUES An electrician had already replaced the variable frequency drives, with no effect, so the...

read more

The Case of the Miscalculating Rock Saw

THE MYSTERY A quarry providing limestone for construction and landscaping called ACES because their rock saw wasn’t cutting stone to the proper width. The saw operator had to subtract 1?8” from each cut to arrive at the proper stone width.THE CLUES The operator said...

read more

The Case of the Stalling Tortilla Press

THE MYSTERY A local chip maker called because their tortilla press would run fine for awhile, but then during the middle of a cycle the press would come down and not return to the up position. Cycling power to the machine it would resume operation sometimes for hours...

read more

The Case of the Obsolete PLCs

THE MYSTERY A municipal water plant was stuck with an unresponsive system of 28 PLCs and an AWOL dealer. The case of the obsolete PLCs. Every vendor the client talked to insisted a whole new system was the only way to get the plant back up to speed again.THE CLUES The...

read more

The Case of the Jerky Oven Door

THE MYSTERY An avionics supplier had been wrestling with a jerky, stubborn, catching oven door for years. All attempts at repair had failed. The case of the jerky oven door.THE CLUES Upon close investigation, the ACES CSI on the scene discovered that the gear box was...

read more